summaryrefslogtreecommitdiff
AgeCommit message (Expand)Author
2000-01-01Set output on for wide-PW cal of wide-PW models, because terminations can loa...HEADINSTRUMENT_6_4_39masterMike
2000-01-01revert support of 3-pin keypad alarm configuration, but keep streamlined codeINSTRUMENT_6_4_38bMike
2000-01-01ignore jig alarm input on older keypads with 3 alarm inputsINSTRUMENT_6_4_38Mike
2000-01-01Disable frequency-related error checking if not in internal modeINSTRUMENT_6_4_37Mike
2000-01-01report max change in cal correctly, by comparing using fabs on both sidesINSTRUMENT_6_4_36Mike
2000-01-01make sure PW shift tweak works in 156E, fixes change from 6.4.29 aimed at AVP...INSTRUMENT_6_4_35Mike
2000-01-01set distort dac to mid-range while calibrating OS, for 1041 offset nullingINSTRUMENT_6_4_34Mike
2000-01-01Sleep time is now fraction of max based on DAC changeINSTRUMENT_6_4_33Mike
2000-01-01add TODO for MondayMike
2000-01-01do not add redundant settling time flag when changing ampl modeMike
2000-01-01further refinements to ampl settling time, but need to make it dependent on s...Mike
2023-11-10add an amplitude settling time for SN 14256 repair and future unitsMichael J. Chudobiak
2000-01-01tweak zout-based duty cycle error check to allow max duty cycle to actually b...INSTRUMENT_6_4_32Mike
2000-01-01version bumpINSTRUMENT_6_4_31Mike
2000-01-01fix VXI timeout bugMike
2000-01-01bump default min PW from 25 to 30 ns due to use of 74HCT151 instead of 74ACT151INSTRUMENT_6_4_30Mike
2000-01-01version bumpINSTRUMENT_6_4_29Mike
2000-01-01Do not apply polarity-based PW shift in bot range if bot range is voltage con...Mike
2000-01-01version bumpINSTRUMENT_6_4_28Mike
2000-01-01fix determination of when to use negative monitor configsMike
2000-01-01delete an unused variableMike
2000-01-01Fix crashes caused by uninitialized pointerMike
2000-01-01reduce ampl_zero_equiv by a factor of 10 in -LV attenuator modeINSTRUMENT_6_4_27cMike
2000-01-01extended delay when switching attenuators in -LV unitsMike
2000-01-01only use attenuators in switchable zout units whem zout is 50 OhmsINSTRUMENT_6_4_27bMike
2000-01-01simplify checks for enabled switchable_zoutMike
2000-01-01misc fixes to max zout checksINSTRUMENT_6_4_27Mike
2000-01-01version bumpMike
2000-01-01first attempt at adding lower duty limit when ZOUT=MAX, for -LV optionMike
2000-01-01version bumpINSTRUMENT_6_4_26Mike
2000-01-01toggle min PW module on powerup also, due to use of IL710 in PCB 340A/BMike
2000-01-01version bumpINSTRUMENT_6_4_25Mike
2000-01-01Test encoder against min change and min speed, for free-rolling defective enc...Mike
2000-01-01version bumpINSTRUMENT_6_4_24Mike
2000-01-01Do not switch polarity relay line in dual-chan dual-pol units, if CH2 ignores...Mike
2000-01-01Major reworking. Set_VI_Control now stores its calculation results for later ...INSTRUMENT_6_4_23dMike
2000-01-01fully implement disable timing cal percentage checkMike
2000-01-01debug messages showing XTR line changesINSTRUMENT_6_4_23cMike
2000-01-01remove broken CH2 TTL/ECL logic code, not used in any instruments nowMike
2000-01-01+/- button not working as expected first press after turn-on, fixed. Better d...Mike
2000-01-01Allow CH2 DLY to control trigger PW (for -2CHX). Better debug messages.INSTRUMENT_6_4_23bMike
2000-01-01version bumpINSTRUMENT_6_4_23Mike
2000-01-01Dump valid points to console when querying range info, to debug errant cal po...Mike
2000-01-01version bumpINSTRUMENT_6_4_22Mike
2000-01-01add ability to temporarily disable timing cal percentage check, for burst/sep...Mike
2000-01-01version bumpINSTRUMENT_6_4_21Mike
2020-07-27add support for new jig pin on keypad 104GMichael J. Chudobiak
2000-01-01version bumpINSTRUMENT_6_4_20Mike
2000-01-01Only ignore polarity when shown to user. Use polarity when considering calibr...Mike
2000-01-01let rise time go to the lowest hardware-possible value, not just the specifie...INSTRUMENT_6_4_19cMike