index
:
Instrument.git
master
pinmuxindt
vxi
The instrument daemon
git repository hosting
summary
refs
log
tree
commit
diff
log msg
author
committer
range
Age
Commit message (
Collapse
)
Author
2020-03-18
version bump
INSTRUMENT_6_4_17
Michael J. Chudobiak
2020-03-18
add an "ALIVE" output, to switch on VCC2 in AVRQ (for example)
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_16
Mike
2000-01-01
allow mult/div by 10 of burst count values
Mike
2000-01-01
Simplify needlessly complex error handling when adjusting encoder
Mike
2000-01-01
Simplify needlessly complex error handling when mult/div menu values
Mike
2000-01-01
Don't move arrow if only one mode. Fix amplitude mode list.
INSTRUMENT_6_4_15b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_15
Mike
2000-01-01
tidy amplitude menu code
Mike
2000-01-01
Don't write GPIB address to flash until CHANGE button pressed, to avoid ↵
Mike
weird pauses
2000-01-01
version bump
INSTRUMENT_6_4_14
Mike
2000-01-01
another divide-by-zero error
Mike
2000-01-01
version bump
INSTRUMENT_6_4_13
Mike
2019-07-16
forward port of avg_error calc divide-by-zero fix from AVR-8A-B-P-QTKB repair
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_12
Mike
2000-01-01
do not reset state before calibrating rise time in AVRQ
Mike
2019-01-08
version bump
INSTRUMENT_6_4_11
Michael J. Chudobiak
2019-01-08
always enable vxi now
Michael J. Chudobiak
2000-01-01
fix min/max ampl/vout balancing when nulling delay shift cal
INSTRUMENT_6_4_10b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_10
Mike
2000-01-01
fix ampl min/max checks when max_ampl is limited by max_vout (some -OT units)
Mike
2018-11-23
version bump
INSTRUMENT_6_4_09
Michael J. Chudobiak
2018-11-23
enable VXI on unprogrammed boards, for testing without GPIB
Michael J. Chudobiak
2000-01-01
make max step size deviation configurable
INSTRUMENT_6_4_08b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_08
Mike
2000-01-01
better monitor averaging (for AVO-8E3 S/N 13790) with auto-reset of average
Mike
2000-01-01
reduce duplicate prompts in multi-line handling
INSTRUMENT_6_4_07c
Mike
2000-01-01
make force_output_fully_off work properly for 2-channel units
INSTRUMENT_6_4_07b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_07
Mike
2000-01-01
indent last commit properly
Mike
2000-01-01
Split inputs into separate lines when multiple interactive commands are received
Mike
2000-01-01
version bump
INSTRUMENT_6_4_06
Mike
2000-01-01
fix duty cycle calculation when calibrating amplitude
Mike
2018-08-14
only check pw_rc limit if greater than zero
INSTRUMENT_6_4_05b
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_05
Mike
2000-01-01
most error checks now used rationalized limit-check functions
Mike
2000-01-01
Revert portion of last for burst control. Deal with later. Report error only ↵
Mike
if count>1
2000-01-01
use standard functions to do simple positive min/max error checks
Mike
2000-01-01
rename some error messages that flag inappropriate config values
Mike
2000-01-01
calculate freq-based limits and errors in all modes, not just internal ↵
Mike
trigger mode
2000-01-01
added hvps_avg_curr_limit for AVR-8F-B
Mike
2000-01-01
add cap_for_pw_rc_limit for AVR-8F-B
Mike
2000-01-01
version bump
INSTRUMENT_6_4_04
Mike
2000-01-01
expansion DACs default to zero at power-up
Mike
2000-01-01
implement full control of DACs 8-15
Mike
2000-01-01
Allow up to 16 DACs, by adding PCB 313A
Mike
2000-01-01
define new I2C ports for PCB 313A DAC board
Mike
2000-01-01
version bump
INSTRUMENT_6_4_03c
Mike
2000-01-01
make drive polarity of zout relay configurable for -R50 units and PCB 308A
INSTRUMENT_6_4_03b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_02
Mike
[next]