index
:
Instrument.git
master
pinmuxindt
vxi
The instrument daemon
git repository hosting
summary
refs
log
tree
commit
diff
log msg
author
committer
range
Age
Commit message (
Collapse
)
Author
2000-01-01
only use attenuators in switchable zout units whem zout is 50 Ohms
INSTRUMENT_6_4_27b
Mike
2000-01-01
simplify checks for enabled switchable_zout
Mike
2000-01-01
misc fixes to max zout checks
INSTRUMENT_6_4_27
Mike
2000-01-01
version bump
Mike
2000-01-01
first attempt at adding lower duty limit when ZOUT=MAX, for -LV option
Mike
2000-01-01
version bump
INSTRUMENT_6_4_26
Mike
2000-01-01
toggle min PW module on powerup also, due to use of IL710 in PCB 340A/B
Mike
2000-01-01
version bump
INSTRUMENT_6_4_25
Mike
2000-01-01
Test encoder against min change and min speed, for free-rolling defective ↵
Mike
encoders
2000-01-01
version bump
INSTRUMENT_6_4_24
Mike
2000-01-01
Do not switch polarity relay line in dual-chan dual-pol units, if CH2 ↵
Mike
ignores POL (like AVRK-DPF)
2000-01-01
Major reworking. Set_VI_Control now stores its calculation results for later ↵
INSTRUMENT_6_4_23d
Mike
reference. This fixes the problem of adding cal points to parameters with large adjustments. The x values are now correct, but the user must still manually compensate for y changes.
2000-01-01
fully implement disable timing cal percentage check
Mike
2000-01-01
debug messages showing XTR line changes
INSTRUMENT_6_4_23c
Mike
2000-01-01
remove broken CH2 TTL/ECL logic code, not used in any instruments now
Mike
2000-01-01
+/- button not working as expected first press after turn-on, fixed. Better ↵
Mike
debugging messages.
2000-01-01
Allow CH2 DLY to control trigger PW (for -2CHX). Better debug messages.
INSTRUMENT_6_4_23b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_23
Mike
2000-01-01
Dump valid points to console when querying range info, to debug errant cal ↵
Mike
points
2000-01-01
version bump
INSTRUMENT_6_4_22
Mike
2000-01-01
add ability to temporarily disable timing cal percentage check, for ↵
Mike
burst/sep/dly2
2000-01-01
version bump
INSTRUMENT_6_4_21
Mike
2020-07-27
add support for new jig pin on keypad 104G
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_20
Mike
2000-01-01
Only ignore polarity when shown to user. Use polarity when considering ↵
Mike
calibration ranges.
2000-01-01
let rise time go to the lowest hardware-possible value, not just the ↵
INSTRUMENT_6_4_19c
Mike
specified minimum - for AVRQ
2000-01-01
reduce min rise time cal points to reflect faster 266D
Mike
2000-01-01
same as last, missed a spot
INSTRUMENT_6_4_19b
Mike
2000-01-01
tagged for 6.4.19
INSTRUMENT_6_4_19
Mike
2000-01-01
ampl_zero_equiv can be large in some AVRQ units, use smallest_allowed_number ↵
Mike
for comparisons instead
2000-01-01
fix encoder clearing
INSTRUMENT_6_4_18b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_18
Mike
2000-01-01
ignore tiniest encoder steps
Mike
2020-03-18
version bump
INSTRUMENT_6_4_17
Michael J. Chudobiak
2020-03-18
add an "ALIVE" output, to switch on VCC2 in AVRQ (for example)
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_16
Mike
2000-01-01
allow mult/div by 10 of burst count values
Mike
2000-01-01
Simplify needlessly complex error handling when adjusting encoder
Mike
2000-01-01
Simplify needlessly complex error handling when mult/div menu values
Mike
2000-01-01
Don't move arrow if only one mode. Fix amplitude mode list.
INSTRUMENT_6_4_15b
Mike
2000-01-01
version bump
INSTRUMENT_6_4_15
Mike
2000-01-01
tidy amplitude menu code
Mike
2000-01-01
Don't write GPIB address to flash until CHANGE button pressed, to avoid ↵
Mike
weird pauses
2000-01-01
version bump
INSTRUMENT_6_4_14
Mike
2000-01-01
another divide-by-zero error
Mike
2000-01-01
version bump
INSTRUMENT_6_4_13
Mike
2019-07-16
forward port of avg_error calc divide-by-zero fix from AVR-8A-B-P-QTKB repair
Michael J. Chudobiak
2000-01-01
version bump
INSTRUMENT_6_4_12
Mike
2000-01-01
do not reset state before calibrating rise time in AVRQ
Mike
2019-01-08
version bump
INSTRUMENT_6_4_11
Michael J. Chudobiak
[next]