Age | Commit message (Expand) | Author |
2000-01-01 | better abstraction of method of switching voltage-controlled PW range, for cl... | Mike |
2000-01-01 | better limits on freq/pw for large burst sep calibration | Mike |
2017-10-05 | renamed some variables in cal_add for clarity | Michael J. Chudobiak |
2017-10-05 | auto-handle the EA V1 distort data when deleting an ampl cal point | root |
2017-10-05 | rename variables in cal_del for clarity | Michael J. Chudobiak |
2017-10-05 | set aux word when setting nominal amplitude, for EA V1INSTRUMENT_6_2_28b | Michael J. Chudobiak |
2000-01-01 | implement ampl-dependent arbitrary voltage output - for AVR-E5-B S/N 13618 | Mike |
2000-01-01 | Rename piece-wise-linear variables for clarity, dropping reference to obsolet... | Mike |
2000-01-01 | replace pol_norm and pol_complement with NO/YES for clarity | Mike |
2000-01-01 | rename "polarity" variables to "inverted" for clarity | Mike |
2000-01-01 | set advance mode for delay test modeINSTRUMENT_6_2_26 | Mike |
2000-01-01 | don't enable delay test mode for CH2INSTRUMENT_6_2_25b | Mike |
2000-01-01 | don't do as many error checks when delay word/range is overriddenINSTRUMENT_6_2_25 | Mike |
2000-01-01 | more specific errors during cal min/max check, and more initial cal points | Mike |
2017-05-23 | fix min/max cal point check for units with non-zero rst amplitude (AVRQ-5-B-AHV) | Michael J. Chudobiak |
1970-01-01 | Enforce minimum ampl magnitude (based on zero_equiv_ampl) in AVRQ -AHV, -XHV ... | mjc |
2000-01-01 | self-cal needs at least 2 periods for PW cal measurement time | mjc |
2000-01-01 | make self-cal min count configurable | mjc |
2000-01-01 | make self-cal reference frequency configurable | Mike |
2000-01-01 | added ability to increase output-on delay | Mike |
2000-01-01 | added get_float_with_min function | Mike |
2000-01-01 | added get_bounded_float function | Mike |
2017-03-22 | reduced minimum self-cal measurement from 100us to 40us (0.25% resolution) | Michael J. Chudobiak |
2016-12-12 | Revert force-output-on during timing cal option. Too complex, little reward. | Michael J. Chudobiak |
1970-01-01 | allow option to force output on during timing cal | root |
1970-01-01 | fix non-working linear interpolation, = vs == | root |
2000-01-01 | set minimum allowed PRF during PW/delay calibration | root |
2000-01-01 | remove failed 3 point interpolation scheme | root |
2000-01-01 | add, but don't use, 3 pt inversion interpolation - doesn't work well! | root |
2000-01-01 | separate function for inverse interpolation of X given desired Y | root |
2000-01-01 | separate function for linear interpolation of X given desired Y | root |
1970-01-01 | add PW distortion for AVR-E, AVIR, AVL. 0% at max amplitude, 100% below set v...INSTRUMENT_6_2_11b | root |
1970-01-01 | fix error in pw/delay control introduced by voltage-controlled 2CH delay | root |
1970-01-01 | for 2CHPP CH2 delay cal, use existing parameters | root |
1970-01-01 | use delay magnitude to set test PRF since it can be negative, and simplify ex... | root |
1970-01-01 | first attempt at implementing CH2 2CHPP delay function | root |
1970-01-01 | move attenuator code out of CH1-only block, so it works for CH2INSTRUMENT_6_2_09c | root |
1970-01-01 | use XTR1 and XTR4 for dual-channel single attenuators, not XTR1 and XTR2 | root |
1970-01-01 | do not set XTR polarity line for CH2 if not dual-polarity, to save XTR lines | root |
1970-01-01 | handle default delay better for CH2 of 2CHPP | root |
2016-04-29 | implement CH2 attenuator ranges | Michael J. Chudobiak |
1970-01-01 | added support for sequential vs binary attenuator stages | root |
1970-01-01 | show FW version and controller type (BB or OL) at startupINSTRUMENT_6_2_03 | root |
2016-02-18 | different serial ports on Olimex | Michael J. Chudobiak |
1970-01-01 | add mutex around remounting, and add debug messagesINSTRUMENT_6_2_02 | root |
1970-01-01 | fix rs232 and flash initialization | root |
1970-01-01 | file root normally read-only now, for safe power-off. Major OS changes too.INSTRUMENT_6_2_00 | root |
1970-01-01 | turn output off when switching attenuator ranges | root |
1970-01-01 | multi-attenuator control using PCB 244A | root |
1970-01-01 | add attenuator_count function | root |