Age | Commit message (Collapse) | Author |
|
By default the device control module registers are locked,
preventing any writes to its registers.
Unlock those registers as part of the init flow.
Reviewed-by: Tom Rini <trini@konsulko.com>
Signed-off-by: Andreas Dannenberg <dannenberg@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
|
|
AM654 allows for booting from primary or backup boot media.
Both media can be chosen individually based on switch settings.
ROM looks for a valid image in primary boot media, if not found
then looks in backup boot media. In order to pass this boot media
information to boot loader, ROM stores a value at a particular
address. Add support for reading this information and determining
the boot media correctly.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: Andreas Dannenberg <dannenberg@ti.com>
Signed-off-by: Vignesh R <vigneshr@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
|
|
The AM654 device is designed for industrial automation and PLC
controller class platforms among other applications. Introduce
base support for AM654 SoC.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
|