Age | Commit message (Collapse) | Author |
|
At present devices use a simple integer offset to record the device tree
node associated with the device. In preparation for supporting a live
device tree, which uses a node pointer instead, refactor existing code to
access this field through an inline function.
Signed-off-by: Simon Glass <sjg@chromium.org>
|
|
To be able to represent the skip-init platdata element with OF_CONTROL,
it needs to be read from the device tree as well and put into the platform data.
Cc: Eric Anholt <eric@anholt.net>
Signed-off-by: Fabian Vogt <fvogt@suse.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
|
|
For Raspberry Pi, we had the input clock rate to the pl011 fixed in
the rpi.c file, but it may be changed by firmware due to user changes
to config.txt. Since the firmware always sets up the uart (default
115200 output unless the user changes it), we can just skip our own
uart init to simplify the boot process and more reliably get serial
output.
Signed-off-by: Eric Anholt <eric@anholt.net>
Reviewed-by: Tom Rini <trini@konsulko.com>
Tested-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
This patch adds an ability to use pl01x as a debug UART. It must
be configured like other types of debug UARTs
Signed-off-by: Sergey Temerkhanov <s.temerkhanov@gmail.com>
Signed-off-by: Radha Mohan Chintakuntla <rchintakuntla@cavium.com>
[trini: Update for _debug_uart_init change]
Acked-by: Simon Glass <sjg@chromium.org>
Signed-off-by: Tom Rini <trini@konsulko.com>
|
|
This arch does not seem to be supported / used at all in the current
U-Boot mainline source tree any more. So lets remove the core u8500 code
and code that was only referenced by this platform.
Please note that this patch also removes these config options:
- CONFIG_PL011_SERIAL_RLCR
- CONFIG_PL011_SERIAL_FLUSH_ON_INIT
As they only seem to be referenced by u8500 based boards. Without any
such board in the current code, these config option don't make sense
any more. Lets remove them as well.
If someone still wants to use this platform, then please send patches
to re-enable support by adding at least one board that references this
code.
Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Cc: John Rigby <john.rigby@linaro.org>
Cc: Simon Glass <sjg@chromium.org>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
Cc: Tom Rini <trini@konsulko.com>
Cc: Heiko Schocher <hs@denx.de>
Cc: Albert Aribaud <albert.u.boot@aribaud.net>
Reviewed-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
|
This is a convenient way for a driver to get the hardware address of a
device, when regmap or syscon are not being used. Change existing callers
to use it as an example to others.
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Joe Hershberger <joe.hershberger@ni.com>
Acked-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
We have flipped CONFIG_SPL_DISABLE_OF_CONTROL. We have cleansing
devices, $(SPL_) and CONFIG_IS_ENABLED(), so we are ready to clear
away the ugly logic in include/fdtdec.h:
#ifdef CONFIG_OF_CONTROL
# if defined(CONFIG_SPL_BUILD) && !defined(SPL_OF_CONTROL)
# define OF_CONTROL 0
# else
# define OF_CONTROL 1
# endif
#else
# define OF_CONTROL 0
#endif
Now CONFIG_IS_ENABLED(OF_CONTROL) is the substitute. It refers to
CONFIG_OF_CONTROL for U-boot proper and CONFIG_SPL_OF_CONTROL for
SPL.
Also, we no longer have to cancel CONFIG_OF_CONTROL in
include/config_uncmd_spl.h and scripts/Makefile.spl.
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
|
|
This patch adds device tree support for arm pl010/pl011 driver.
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
commit aed2fbef5e9a0ab5a7cd01e742039a962f0b24ef
"dm: serial: Tidy up the pl01x driver"
caused a regression on (real hardware) PL010 by omitting
to update the line control register when switching baudrate.
Fix this by inlining the missing write to the baud control
register.
Also renaming the set_line_control() function to
pl011_set_line_control() since this function is clearly
PL011-specific, and it won't suffice to call that to
set up line control.
Tested on the Integrator/AP hardware.
Cc: Simon Glass <sjg@chromium.org>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
|
|
The private data size is missing from the driver, so we store it at 0,
which causes problems when something overwrites memory at 0.
Fix this.
Change-Id: I6f551ee905b0064ae8343e41e46450c37c8c8c1a
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
pl010 & pl011 have different control register offsets, setting it as per
the pl01x type.
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
Receive line control uses same setting as transmit line control, also one lcrh
write is effective for both baud rate & receive line control internal update.
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
UART_IBRD, UART_FBRD, and UART_LCR_H form a single 30-bit wide register which
is updated on a single write strobe generated by a UART_LCR_H write. So, to
internally update the content of UART_IBRD or UART_FBRD, a write to UART_LCR_H
must always be performed at the end.
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
Although we were checking the pl01x type, seems like PL010 type was being
passed by mistake.
Signed-off-by: Vikas Manocha <vikas.manocha@st.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
The platform_data definitions are generally referenced from both
drivers and board files. That is why header files defining
platform_data sturectures are placed in "include" directory,
but our top level "include" directory is already too cluttered.
Let's collect platform_data definitions under the directory
"include/dm/platform_data" like Linux gathers ones around under
"include/linux/platform_data".
This commit moves two header files:
include/serial_mxc.h -> include/dm/platform_data/serial_mxc.h
include/serial_pl01x.h -> include/dm/platform_data/serial_pl01x.h
Signed-off-by: Masahiro Yamada <yamada.m@jp.panasonic.com>
|
|
Add driver model support in this driver, using platform data provided by
the board.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
Adjust the driver so that leaf functions take a pointer to the serial port
register base. Put all the global configuration in the init function, and
use the same settings from then on.
This makes it much easier to move to driver model without duplicating the
code, since with driver model we use platform data rather than global
settings.
The driver is compiled with either the CONFIG_PL010_SERIAL or
CONFIG_PL011_SERIAL option and this determines the uart type. With driver
model this needs to come in from platform data, so create a new
CONFIG_PL01X_SERIAL config which brings in the driver, and adjust the
driver to support both peripheral variants.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
Signed-off-by: Wolfgang Denk <wd@denx.de>
[trini: Fixup common/cmd_io.c]
Signed-off-by: Tom Rini <trini@ti.com>
|
|
If the pl011 is connected to another device which has hardware
flow-control on, characters are never received by the pl011.
Asserting RTS when flow-control is off will have no effect.
This is in line with how Linux behaves.
Signed-off-by: Joshua Housh <joshua.housh@calxeda.com>
Tested-by: Marek Vasut <marex@denx.de>
|
|
Replace the in-place ad-hoc implementation of serial_puts() within
the drivers with default_serial_puts() call. This cuts down on the
code duplication quite a bit.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marek Vasut <marek.vasut@gmail.com>
Cc: Tom Rini <trini@ti.com>
|
|
Remove the support for not-CONFIG_SERIAL_MULTI part from serial
port drivers and some board files. Since CONFIG_SERIAL_MULTI is
now enabled by default, that part is a dead code. Remove it.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marek Vasut <marek.vasut@gmail.com>
Cc: Anatolij Gustschin <agust@denx.de>
Cc: Stefan Roese <sr@denx.de>
Signed-off-by: Tom Rini <trini@ti.com>
|
|
Implement support for CONFIG_SERIAL_MULTI into pl01x serial driver.
This driver was so far only usable directly, but this patch also adds
support for the multi method. This allows using more than one serial
driver alongside the pl01x driver. Also, add a weak implementation
of default_serial_console() returning this driver.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marek Vasut <marek.vasut@gmail.com>
Cc: Tom Rini <trini@ti.com>
Cc: Stefano Babic <sbabic@denx.de>
Cc: Mathieu J. Poirier <mathieu.poirier@linaro.org>
Cc: Linus Walleij <linus.walleij@linaro.org>
Cc: John Rigby <john.rigby@linaro.org>
Cc: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
Signed-off-by: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: John Rigby <john.rigby@linaro.org>
Acked-by: Tom Rini <trini@ti.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Conflicts:
drivers/gpio/Makefile
|
|
Not draining the FIFO and waiting for the UART to be non-busy
before changing baudrate results in crap characters on the
console, so let's wait for the FIFO to drain and the last
character to be clocked out before we do that.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
|
|
Two new options:
CONFIG_PL011_SERIAL_RLCR
Some vendor versions of PL011 serial ports (e.g. ST-Ericsson U8500)
have separate receive and transmit line control registers. Set
this variable to initialize the extra register.
CONFIG_PL011_SERIAL_FLUSH_ON_INIT
On some platforms (e.g. U8500) U-Boot is loaded by a second stage
boot loader that has already initialized the UART. Define this
variable to flush the UART at init time.
empty fifo on init
Signed-off-by: John Rigby <john.rigby@linaro.org>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
Use C structs for registers, and use readl/writel instead of custom
accessors.
Acked-by: Michael Brandt <michael.brandt@stericsson.com>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
The pl01x serial driver was lacking the code to switch baudrates from the
command line. Fixed by simply saving the new baudrate and calling
serial_init() again. Also fixed CamelCase variables, I/O accessors and
comment style.
Signed-off-by: Matt Waddel <matt.waddel@linaro.org>
|
|
Signed-off-by: Andreas Engel <andreas.engel@ericsson.com>
|
|
They only differ in the init function.
This also adds the missing watchdog support for the PL011.
Signed-off-by: Andreas Engel <andreas.engel@ericsson.com>
|