diff options
author | York Sun <york.sun@nxp.com> | 2016-12-28 08:43:42 -0800 |
---|---|---|
committer | Tom Rini <trini@konsulko.com> | 2017-01-04 19:40:44 -0500 |
commit | c01e4a1a6f4ff8cbfa1fcdf984903e746cca3f66 (patch) | |
tree | b3c958b568968e52d3a09e4fe77e143e40432ee4 /arch/powerpc/cpu | |
parent | ba1b6fb5cc86cb603c396d465cf5dac11ccab0b3 (diff) |
mmc: move CONFIG_SYS_FSL_ERRATUM_ESDHC* to Kconfig
Add option SYS_FSL_ERRATUM_ESDHC111, SYS_FSL_ERRATUM_ESDHC13,
SYS_FSL_ERRATUM_ESDHC135, SYS_FSL_ERRATUM_ESDHC_A001 to mmc Kconfig.
Move existing macros to related Kconfig.
Signed-off-by: York Sun <york.sun@nxp.com>
[trini: Migrate bk4r1]
Signed-off-by: Tom Rini <trini@konsulko.com>
Diffstat (limited to 'arch/powerpc/cpu')
-rw-r--r-- | arch/powerpc/cpu/mpc83xx/Kconfig | 3 | ||||
-rw-r--r-- | arch/powerpc/cpu/mpc85xx/Kconfig | 25 |
2 files changed, 28 insertions, 0 deletions
diff --git a/arch/powerpc/cpu/mpc83xx/Kconfig b/arch/powerpc/cpu/mpc83xx/Kconfig index 6e4a93172f..184063c40b 100644 --- a/arch/powerpc/cpu/mpc83xx/Kconfig +++ b/arch/powerpc/cpu/mpc83xx/Kconfig @@ -22,6 +22,7 @@ config TARGET_VME8349 config TARGET_MPC8308RDB bool "Support MPC8308RDB" + select SYS_FSL_ERRATUM_ESDHC111 config TARGET_MPC8313ERDB bool "Support MPC8313ERDB" @@ -69,9 +70,11 @@ config TARGET_TQM834X config TARGET_HRCON bool "Support hrcon" + select SYS_FSL_ERRATUM_ESDHC111 config TARGET_STRIDER bool "Support strider" + select SYS_FSL_ERRATUM_ESDHC111 endchoice diff --git a/arch/powerpc/cpu/mpc85xx/Kconfig b/arch/powerpc/cpu/mpc85xx/Kconfig index 307a45d6c4..0a4fa42b21 100644 --- a/arch/powerpc/cpu/mpc85xx/Kconfig +++ b/arch/powerpc/cpu/mpc85xx/Kconfig @@ -348,6 +348,7 @@ config ARCH_B4860 config ARCH_BSC9131 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -356,6 +357,7 @@ config ARCH_BSC9131 config ARCH_BSC9132 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -365,6 +367,7 @@ config ARCH_BSC9132 config ARCH_C29X bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -455,6 +458,7 @@ config ARCH_MPC8572 config ARCH_P1010 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -464,6 +468,7 @@ config ARCH_P1010 config ARCH_P1011 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -473,6 +478,7 @@ config ARCH_P1011 config ARCH_P1020 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -482,6 +488,7 @@ config ARCH_P1020 config ARCH_P1021 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -491,6 +498,7 @@ config ARCH_P1021 config ARCH_P1022 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -508,6 +516,7 @@ config ARCH_P1023 config ARCH_P1024 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -517,6 +526,7 @@ config ARCH_P1024 config ARCH_P1025 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -526,6 +536,8 @@ config ARCH_P1025 config ARCH_P2020 bool select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 + select SYS_FSL_ERRATUM_ESDHC_A001 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -536,6 +548,7 @@ config ARCH_P2041 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -545,6 +558,7 @@ config ARCH_P3041 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -554,6 +568,9 @@ config ARCH_P4080 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 + select SYS_FSL_ERRATUM_ESDHC13 + select SYS_FSL_ERRATUM_ESDHC135 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -563,6 +580,7 @@ config ARCH_P5020 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -572,6 +590,7 @@ config ARCH_P5040 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -584,6 +603,7 @@ config ARCH_T1023 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_DDR4 select SYS_FSL_HAS_SEC @@ -594,6 +614,7 @@ config ARCH_T1024 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_DDR4 select SYS_FSL_HAS_SEC @@ -604,6 +625,7 @@ config ARCH_T1040 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_DDR4 select SYS_FSL_HAS_SEC @@ -614,6 +636,7 @@ config ARCH_T1042 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_DDR4 select SYS_FSL_HAS_SEC @@ -624,6 +647,7 @@ config ARCH_T2080 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE @@ -633,6 +657,7 @@ config ARCH_T2081 bool select E500MC select FSL_LAW + select SYS_FSL_ERRATUM_ESDHC111 select SYS_FSL_HAS_DDR3 select SYS_FSL_HAS_SEC select SYS_FSL_SEC_BE |