Age | Commit message (Collapse) | Author |
|
There are a lot of unrelated files in common, including all of the commands.
Moving them into their own directory makes them easier to find and is more
logical.
Some commands include non-command code, such as cmd_scsi.c. This should be
sorted out at some point so that the function can be enabled with or without
the associated command.
Unfortunately, with m68k I get this error:
m68k: + M5329AFEE
+arch/m68k/cpu/mcf532x/start.o: In function `_start':
+arch/m68k/cpu/mcf532x/start.S:159:(.text+0x452): relocation truncated to fit: R_68K_PC16 against symbol `board_init_f' defined in .text.board_init_f section in common/built-in.o
I hope someone can shed some light on what this means. I hope it isn't
depending on the position of code in the image.
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Heiko Schocher <hs@denx.de>
Acked-by: Stefan Roese <sr@denx.de>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
|
|
It is convenient to be able to see the status of all regulators in a list.
Add this feature to the 'reg status' command.
Signed-off-by: Simon Glass <sjg@chromium.org>
|
|
When a regulator command cannot honour the requested voltage, display the
limits to try to be helpful.
Signed-off-by: Simon Glass <sjg@chromium.org>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
|
|
This commit cleanups the regulator command.
The first change, is adjusting "regulator dev" command to use
"regulator-name" constraint, for setting the operating device.
Thanks to this, the regulator_get() function is removed.
This also updates do_list() function, with loop over uclass_find_*
function calls, to prevent probe of all listed regulators.
This also cleanups the printing in command.
Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Simon Glass <sjg@chromium.org>
Tested on sandbox:
Tested-by: Simon Glass <sjg@chromium.org>
|
|
This command is based on driver model regulator's API.
The user interface provides:
- list UCLASS regulator devices
- show or [set] operating regulator device
- print constraints info
- print operating status
- print/[set] voltage value [uV] (force)
- print/[set] current value [uA]
- print/[set] operating mode id
- enable the regulator output
- disable the regulator output
The 'force' option can be used for setting the value which exceeds
the constraints min/max limits.
Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Simon Glass <sjg@chromium.org>
|