Age | Commit message (Collapse) | Author |
|
Since Gen3 SDHI has an internal DS signal AC-spec violation in HS400 mode,
CRC-error may occur in read command in HS400 mode. This phoenomenon occurs
at low/high temperature.
To fix this, after completion of HS400 tuning, enable manual calibration.
However, Gen3 M3 Ver.1.2 or earlier and H3 1.x does not support HS400.
These SoC forcibly use HS200 mode by SoC attribute.
The DT adjustment of the tuning parameters is not supported until the
DT property names become clear.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Adapted from a patch by Takeshi Saito <takeshi.saito.xv@renesas.com>
Cc: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
Cc: Peng Fan <peng.fan@nxp.com>
|
|
Different versions of the SDHI core use either bit 17 or bit 20 for the
DTRAEND indication, which can differ even between SoC revisions. Make
the DTRAEND bit position part of the driver private data, so that the
probe function can set this accordingly. Set this to 20 on Socionext
SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
|
Add support for the HS400 mode to SDHI driver. This uses the up-tune
mechanism from already supported HS200 tuning.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
|
Move the tap_pos variable, which is the HS200/HS400/SDR104 calibration
offset, into private data, so it can be passed around. This is done in
preparation for the HS400 mode, which needs to adjust this value.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
|
Switch the driver to using clk_get_rate()/clk_set_rate() instead of
caching the mclk frequency in it's private data. This is required on
the SDHI variant of the controller, where the upstream mclk need to
be adjusted when using UHS modes.
Platforms which do not support clock framework or do not support it
in eg. SPL default to 100 MHz clock.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
---
V2: - Fix build on certain platforms using SPL without clock framework
V3: - Turn clk_get_rate into a callback and fill it as needed on both
renesas and socionext platforms
|
|
When U-Boot started using SPDX tags we were among the early adopters and
there weren't a lot of other examples to borrow from. So we picked the
area of the file that usually had a full license text and replaced it
with an appropriate SPDX-License-Identifier: entry. Since then, the
Linux Kernel has adopted SPDX tags and they place it as the very first
line in a file (except where shebangs are used, then it's second line)
and with slightly different comment styles than us.
In part due to community overlap, in part due to better tag visibility
and in part for other minor reasons, switch over to that style.
This commit changes all instances where we have a single declared
license in the tag as both the before and after are identical in tag
contents. There's also a few places where I found we did not have a tag
and have introduced one.
Signed-off-by: Tom Rini <trini@konsulko.com>
|
|
Synchronize the naming with Linux, call the common code TMIO.
No functional change.
Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Jaehoon Chung <jh80.chung@samsung.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|