summaryrefslogtreecommitdiff
path: root/drivers/net/phy/Kconfig
blob: 25de3fb2266586bd2b234f81dda702fd68e95a2d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188

config BITBANGMII
	bool "Bit-banged ethernet MII management channel support"

config MV88E6352_SWITCH
	bool "Marvell 88E6352 switch support"

menuconfig PHYLIB
	bool "Ethernet PHY (physical media interface) support"
	depends on NET
	help
	  Enable Ethernet PHY (physical media interface) support.

if PHYLIB

config PHY_ADDR
	int "PHY address"
	default 1 if ARCH_SUNXI
	default 0
	help
	  The address of PHY on MII bus. Usually in range of 0 to 31.

config B53_SWITCH
	bool "Broadcom BCM53xx (RoboSwitch) Ethernet switch PHY support."
	help
	  Enable support for Broadcom BCM53xx (RoboSwitch) Ethernet switches.
	  This currently supports BCM53125 and similar models.

if B53_SWITCH

config B53_CPU_PORT
	int "CPU port"
	default 8

config B53_PHY_PORTS
	hex "Bitmask of PHY ports"

endif # B53_SWITCH

config MV88E61XX_SWITCH
	bool "Marvel MV88E61xx Ethernet switch PHY support."

if MV88E61XX_SWITCH

config MV88E61XX_CPU_PORT
	int "CPU Port"

config MV88E61XX_PHY_PORTS
	hex "Bitmask of PHY Ports"

config MV88E61XX_FIXED_PORTS
	hex "Bitmask of PHYless serdes Ports"

endif # MV88E61XX_SWITCH

config PHYLIB_10G
	bool "Generic 10G PHY support"

config PHY_AQUANTIA
	bool "Aquantia Ethernet PHYs support"

config PHY_ATHEROS
	bool "Atheros Ethernet PHYs support"

config PHY_BROADCOM
	bool "Broadcom Ethernet PHYs support"

config PHY_CORTINA
	bool "Cortina Ethernet PHYs support"

config PHY_DAVICOM
	bool "Davicom Ethernet PHYs support"

config PHY_ET1011C
	bool "LSI TruePHY ET1011C support"

config PHY_LXT
	bool "LXT971 Ethernet PHY support"

config PHY_MARVELL
	bool "Marvell Ethernet PHYs support"

config PHY_MESON_GXL
	bool "Amlogic Meson GXL Internal PHY support"

config PHY_MICREL
	bool "Micrel Ethernet PHYs support"
	help
	  Enable support for the GbE PHYs manufactured by Micrel (now
	  a part of Microchip). This includes drivers for the KSZ804,
	  KSZ8031, KSZ8051, KSZ8081, KSZ8895, KSZ886x, KSZ8721
	  either/or KSZ9021 (see the "Micrel KSZ9021 family support"
	  config option for details), and KSZ9031 (if configured).

if PHY_MICREL

config PHY_MICREL_KSZ9021
	bool
	select PHY_GIGE
	select PHY_MICREL_KSZ90X1

config PHY_MICREL_KSZ9031
	bool
	select PHY_GIGE
	select PHY_MICREL_KSZ90X1

config PHY_MICREL_KSZ90X1
	bool "Micrel KSZ90x1 family support"
	select PHY_GIGE
	help
	  Enable support for the Micrel KSZ9021 and KSZ9031 GbE PHYs. If
	  enabled, the extended register read/write for KSZ90x1 PHYs
	  is supported through the 'mdio' command and any RGMII signal
	  delays configured in the device tree will be applied to the
	  PHY during initialization.

	  This should not be enabled at the same time with PHY_MICREL_KSZ8XXX
	  as the KSZ9021 and KS8721 share the same ID.

config PHY_MICREL_KSZ8XXX
	bool "Micrel KSZ8xxx family support"
	default y if !PHY_MICREL_KSZ90X1
	help
	  Enable support for the 8000 series GbE PHYs manufactured by Micrel
	  (now a part of Microchip). This includes drivers for the KSZ804,
	  KSZ8031, KSZ8051, KSZ8081, KSZ8895, KSZ886x, and KSZ8721.

	  This should not be enabled at the same time with PHY_MICREL_KSZ90X1
	  as the KSZ9021 and KS8721 share the same ID.

endif # PHY_MICREL

config PHY_MSCC
	bool "Microsemi Corp Ethernet PHYs support"

config PHY_NATSEMI
	bool "National Semiconductor Ethernet PHYs support"

config PHY_REALTEK
	bool "Realtek Ethernet PHYs support"

config RTL8211X_PHY_FORCE_MASTER
	bool "Ethernet PHY RTL8211x: force 1000BASE-T master mode"
	depends on PHY_REALTEK
	help
	  Force master mode for 1000BASE-T on RTl8211x PHYs (except for RTL8211F).
	  This can work around link stability and data corruption issues on gigabit
	  links which can occur in slave mode on certain PHYs, e.g. on the
	  RTL8211C(L).

	  Please note that two directly connected devices (i.e. via crossover cable)
	  will not be able to establish a link between each other if they both force
	  master mode. Multiple devices forcing master mode when connected by a
	  network switch do not pose a problem as the switch configures its affected
	  ports into slave mode.

	  This option only affects gigabit links. If you must establish a direct
	  connection between two devices which both force master mode, try forcing
	  the link speed to 100MBit/s.

	  If unsure, say N.

config PHY_SMSC
	bool  "Microchip(SMSC) Ethernet PHYs support"

config PHY_TERANETICS
	bool "Teranetics Ethernet PHYs support"

config PHY_TI
	bool "Texas Instruments Ethernet PHYs support"

config PHY_VITESSE
	bool "Vitesse Ethernet PHYs support"

config PHY_XILINX
	bool "Xilinx Ethernet PHYs support"

config PHY_FIXED
	bool "Fixed-Link PHY"
	depends on DM_ETH
	help
	  Fixed PHY is used for having a 'fixed-link' to another MAC with a direct
	  connection (MII, RGMII, ...).
	  There is nothing like autoneogation and so
	  on, the link is always up with fixed speed and fixed duplex-setting.
	  More information: doc/device-tree-bindings/net/fixed-link.txt

endif #PHYLIB