Adjust the driver so that leaf functions take a pointer to the serial port
register base. Put all the global configuration in the init function, and
use the same settings from then on.
This makes it much easier to move to driver model without duplicating the
code, since with driver model we use platform data rather than global
settings.
The driver is compiled with either the CONFIG_PL010_SERIAL or
CONFIG_PL011_SERIAL option and this determines the uart type. With driver
model this needs to come in from platform data, so create a new
CONFIG_PL01X_SERIAL config which brings in the driver, and adjust the
driver to support both peripheral variants.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Stephen Warren <swarren@wwwdotorg.org>
|
|
Signed-off-by: Wolfgang Denk <wd@denx.de>
[trini: Fixup common/cmd_io.c]
Signed-off-by: Tom Rini <trini@ti.com>
|
|
Two new options:
CONFIG_PL011_SERIAL_RLCR
Some vendor versions of PL011 serial ports (e.g. ST-Ericsson U8500)
have separate receive and transmit line control registers. Set
this variable to initialize the extra register.
CONFIG_PL011_SERIAL_FLUSH_ON_INIT
On some platforms (e.g. U8500) U-Boot is loaded by a second stage
boot loader that has already initialized the UART. Define this
variable to flush the UART at init time.
empty fifo on init
Signed-off-by: John Rigby <john.rigby@linaro.org>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
Use C structs for registers, and use readl/writel instead of custom
accessors.
Acked-by: Michael Brandt <michael.brandt@stericsson.com>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
They only differ in the init function.
This also adds the missing watchdog support for the PL011.
Signed-off-by: Andreas Engel <andreas.engel@ericsson.com>
|